Grundfos / Multiple Principals

Water Treatment Plants

Reverse osmosis, UV disinfection and full water treatment infrastructure for communities, health facilities and industrial water users across Africa.

400 million Africans lack access to safely managed drinking water.

Monitoring alone cannot produce safe drinking water when source water quality is poor. Where dissolved contaminants, fluoride, nitrate or microbiological contamination exceed WHO guidelines, treatment is required before the water is safe to distribute. Jos•Hansen designs and supplies reverse osmosis, UV disinfection and chlorination systems from 500 litres per hour for rural health facilities to 50,000 litres per hour for urban utilities, with every system design beginning from a source water quality analysis.

Water Treatment Plants

RO removes 99%

Reverse osmosis membranes remove dissolved salts, heavy metals, fluoride, nitrate, arsenic and microbiological contaminants to below WHO drinking water guideline concentrations from sources that conventional treatment cannot clean.

UV kills pathogens

Ultraviolet disinfection destroys bacteria, viruses and protozoa including chlorine-resistant Cryptosporidium and Giardia at doses achievable in a single pass, without adding chemicals that create taste or odour.

Remote monitoring

All Jos•Hansen treatment systems include remote monitoring of flow rate, pressure, membrane performance, UV lamp intensity and treated water quality, with automated alerts for any parameter outside operating limits.

Reverse osmosis eliminates dissolved contaminants from any source water.

Every Jos•Hansen treatment system design begins with a source water quality analysis covering pH, conductivity, TDS, turbidity, hardness, iron, manganese, fluoride, nitrate, arsenic and microbial indicators. The treatment process train is specified against the analysis results, ensuring each treatment stage targets the specific contaminants present rather than a generic configuration. Systems designed without source water analysis frequently fail against unforeseen contaminants or are over-engineered for clean sources, wasting capital expenditure.

Reverse osmosis eliminates dissolved contaminants from any source water.

UV disinfection provides pathogen kill without chemical residue.

Medium-pressure UV lamps operating at 254 nm deliver germicidal doses of 40 mJ/cm² or greater for 4-log inactivation of bacteria and viruses and 3-log inactivation of Cryptosporidium and Giardia, meeting WHO disinfection targets without chlorine dosing. UV systems are sized to the specific flow rate and UV transmittance of the water being treated, with online UV intensity monitoring and dose verification to confirm that the required germicidal dose is being delivered at all flow rates. UV disinfection is particularly cost-effective for rural boreholes and springs where chemical dosing infrastructure and chemical supply chains are not reliable.

UV disinfection provides pathogen kill without chemical residue.

Treatment systems are designed from source water analysis, not generic specifications.

Every Jos•Hansen treatment system design begins with a comprehensive source water quality analysis covering at minimum pH, conductivity, TDS, turbidity, hardness, iron, manganese, fluoride, nitrate, arsenic, microbial indicators and any site-specific contaminants of concern. The treatment process train is specified against the analysis results, ensuring that each treatment stage is correctly designed for the specific contaminants present. Systems designed without source water analysis frequently fail against unforeseen contaminants or are over-engineered for clean sources, wasting capital expenditure.

Treatment systems are designed from source water analysis, not generic specifications.

Technical specifications.

RO capacity range

500-50,000 L/hr modular configurations

RO rejection

97-99% TDS; >99% for heavy metals, fluoride, nitrate, microorganisms

UV dose

40 mJ/cm² minimum for 4-log bacterial inactivation

Power options

Grid, solar-plus-battery, generator sized per system requirement

Monitoring

Remote GSM/4G monitoring of flow, pressure, conductivity and UV intensity

Design basis

Source water quality analysis; WHO drinking water guidelines

99%

Dissolved contaminant rejection by reverse osmosis membranes for heavy metals, fluoride, nitrate and microbiological parameters exceeding WHO drinking water guidelines

500 L+

Minimum hourly treatment capacity of Jos•Hansen RO systems, scalable to 50,000 L/hr for community and urban water utility applications

4-log

Pathogen inactivation achieved by UV disinfection at 40 mJ/cm² UV dose against bacteria and viruses without chemical addition

Why Water.

Source water-matched design

Every system is designed from a source water quality analysis, ensuring the treatment process eliminates the specific contaminants present rather than a generic specification.

No chemical taste or odour

UV disinfection and RO produce water free from chlorine residue taste, eliminating consumer resistance that undermines adoption of chlorination systems.

Solar-compatible systems

Treatment systems can be configured with solar power and battery storage for off-grid rural health facilities and community water points.

Full turnkey delivery

Jos•Hansen manages site assessment, system design, procurement, installation, commissioning, operator training and annual maintenance for all treatment systems.

Partner with Jos Hansen

Talk to our procurement and operations teams about your next infrastructure, healthcare or scientific deployment.

100+
Years of Excellence
1,300+
Projects Completed
9+
African Countries
4
Operating Divisions