PTW Dosimetry

QA & Dosimetry Systems

Radiation therapy quality assurance, beam calibration and patient-specific verification.

QA & Dosimetry Systems — QA setup

Every radiotherapy machine must be proven safe before it treats a patient — every day.

PTW Dosimetry is the global reference standard for radiation therapy quality assurance. Its instruments — ionisation chambers, electrometers, water phantoms and patient-specific QA arrays — are used in radiotherapy departments worldwide to verify machine output, characterise beam data and confirm that treatment plans are delivered as prescribed. In Africa, where radiotherapy departments are frequently inspected by national nuclear medicine regulatory authorities, a complete PTW QA programme is both a patient safety requirement and a regulatory prerequisite. Jos•Hansen supplies, commissions and supports the full PTW QA toolchain across East and Southern Africa.

QA & Dosimetry Systems

Compliance

A functioning QA programme is not optional — it is a regulatory requirement for operating a licensed radiotherapy department. PTW systems meet IAEA, AAPM and IPEM standards and produce the documentation required for national nuclear medicine authority inspections.

Patient safety

Pre-treatment patient-specific QA with the OCTAVIUS 4D system measures the actual dose delivered by each IMRT or VMAT plan before the patient receives their first fraction — catching calculation or delivery errors that would otherwise go undetected.

Universality

One PTW toolchain covers every modality in the department: LINACs, CyberKnife, Radixact, Flexitron HDR — the same chambers, electrometer and phantom system validate beam output across all radiotherapy equipment.

Absolute dose calibration — the foundation every treatment plan is built on.

Reference dosimetry establishes the machine output in absolute units (cGy/MU) traceable to national primary standards. PTW's Farmer-type ionisation chambers and UNIDOS webline electrometer provide calibration to IAEA TRS-398 and AAPM TG-51 protocols with measurement uncertainty below 0.5%. This calibration is the anchor for every dose calculation in the treatment planning system — if it is wrong, every patient's prescription is wrong. Jos•Hansen manages annual re-calibration against SSDL/PSDL reference standards.

Absolute dose calibration — the foundation every treatment plan is built on.

Beam characterisation with the MP3-M water phantom.

Commissioning a new radiotherapy machine — or re-commissioning after major service — requires 3D beam data acquisition: percentage depth dose curves, beam profiles, output factors and penumbra measurements across multiple energies and field sizes. The PTW MP3-M motorised water phantom, scanning software and ion chamber array acquire this data systematically and export it directly to major treatment planning systems. Jos•Hansen's medical physicists operate the full beam commissioning programme at every machine installation.

Beam characterisation with the MP3-M water phantom.

Patient-specific QA — verification before the first fraction is delivered.

IMRT and VMAT treatment plans concentrate high doses near critical structures using hundreds of small, modulated segments. The OCTAVIUS 4D system measures the actual delivered dose distribution and compares it to the treatment planning system's predicted dose using gamma analysis. Plans that fail the gamma criteria are identified and re-optimised before the patient is treated. This is the final safety check in the radiotherapy chain — and it is mandatory under IAEA and AAPM recommendations for all IMRT/VMAT programmes.

Patient-specific QA — verification before the first fraction is delivered.

Technical specifications.

Reference dosimetry

PTW Farmer chamber + UNIDOS webline electrometer

Beam scanning

MP3-M motorised water phantom + OmniPro software

Patient-specific QA

OCTAVIUS 4D + 2D array detectors

Calibration standard

IAEA TRS-398 · AAPM TG-51 · IPEM Report 81

Traceability

PSDL / SSDL nationally traceable chain

Machine coverage

LINAC · CyberKnife · TomoTherapy · HDR · proton

<0.5%

Measurement uncertainty of PTW Farmer-type reference ionisation chambers — the precision anchor for all treatment dose calculations

2%/2mm

Standard gamma analysis criteria for IMRT/VMAT patient-specific QA — the international benchmark for plan delivery verification

TRS-398

IAEA absorbed dose to water protocol — the single international standard governing reference dosimetry in all radiotherapy departments

Why QA.

Regulatory prerequisite

PTW QA programmes meet IAEA, AAPM and IPEM standards — producing the inspection documentation required by national nuclear medicine regulatory authorities.

Patient-specific verification

OCTAVIUS 4D catches IMRT/VMAT delivery errors before they reach the patient — a mandatory safety step under IAEA and AAPM recommendations.

Full-department coverage

One PTW toolchain validates every modality — the same reference chambers, electrometer and phantom system work across LINACs, CyberKnife, TomoTherapy and HDR.

Calibration and physics support

Jos•Hansen manages annual re-calibration against SSDL/PSDL standards, consumable supply (chambers, detectors) and physicist training programmes.